Compromised or errant system / device status shown in Q-SYS Reflect.

Issue: When using Q-SYS Connect 10.3 with RMS 1.0.2, users may see incorrect system or device status in Q-SYS Reflect. 

Workaround: None. This will be fixed in a future release.

Earliest Reported Version: Q-SYS Connect 10.3

Version Fixed: This issue will be resolved with a dedicated release for RMS.

 
 

Q-SYS Connect Certificate Configuration Incorrectly Displays Reboot Required Message

Issue: When modifying certificates on a Q-SYS Connect device, the UI incorrectly indicates that a full device reboot is required. A full reboot is not actually necessary for Q-SYS Connect certificate configuration, and only a refresh of the Peripheral Manager (QPM) application is needed.

Workaround: Ignore the reboot prompt displayed in the UI. Instead of performing a full device reboot, refresh the Peripheral Manager (QPM) application to apply the certificate changes.

Earliest Reported Version: Q-SYS Connect 10.3

Version Fixed: This issue will be fixed in a future release.