Factory Reset | Attero Tech un Series Wallplates
Discover how to perform a factory reset on the Attero Tech un Series Wallplates.
Procedure
Use the following steps to reset an Attero Tech un Series wallplate to its factory default settings:
Access to the factory reset button is through a small circular hole on the underside of the unit, next to the ventilation cutouts.
- Insert a small screwdriver or paperclip into the hole to activate the factory reset switch.
- There should be a noticeable “click” when it’s activated.
- Hold the switch in for 5 to 10 seconds then release.
If the factory reset was successful, the unit will reset which will be indicated by the power LED will turning red.
Note
Resetting will restore all the devices parameters back to their factory defaults including all the Dante/AES67 settings such as device name, channel names as well as the device settings such as input select. The devices IP address mode is also reset back to getting a dynamic IP.