How To | Transfer a Configuration from an MP-M40 to an MP-M80

Learn how to easily migrate an existing configuration from an MP-M40 system to an MP-M80, ensuring a seamless experience.

Updated at June 8th, 2023

Procedure


It is possible to save a configuration from an MP-M40 and import that saved configuration on the MP-M80. You can use either a USB drive or a PC to transfer the configuration between mixers.

Expected Behavior

  • The Mic/Line inputs 1-4 on the MP-M40 will line up with the Mic/Line Inputs 1-4 of the MP-M80. The remaining Mic/Line inputs of the MP-M80 will remain at their default settings.
  • The Summed-Mono RCA inputs 5-8 on the MP-M40 will then line up with the Summed-Mono RCA inputs 9-12 on the MP-M80. The remaining Summed-Mono Inputs on the MP-M80 will remain at their default setting.
  • The Output Zones 1-4 on the MP-M40 will line up with the Output Zones 1-4 on the MP-M80. The remaining Output Zones 5-8 of the MP-M80 will remain at their default settings.
  • All DSP processing shall be saved and applied to their respective input and output channels.

Saving the Configuration on the MP-M40

  1. Establish a good network connection to the MP-M40.
  2. With MP Install, navigate to MENU > CONFIGURATIONS.
  3. Save last configuration on the MP-M40 that is to be transferred over to the MP-M80 to the MP-M Internal Storage location.
  4. Copy the configuration either to a USB Drive or to the MP Install App Storage location.
    • If using a USB drive, insert the USB drive (formatted for FAT32) into either USB port on the MP-M and then copy the configuration from the Internal Storage location to the USB drive.
    • If using a PC, copy the configuration from the Internal Storage to the App Storage. The default directory for the App Storage is C:/Users/<user name>/Document/QSC.

Recalling the Configuration on the MP-M80 - USB Drive

  1. Establish a network connection to the MP-M80.
  2. Insert the USB drive with the configuration into either of the two USB ports on the MP-M.
  3. On a PC or tablet running MP Install, navigate to MENU > CONFIGURATIONS.
  4. Select the configuration listed on the USB drive.
  5. Copy the configuration from the USB drive to the Internal Storage.
  6. Once copied, select the configuration and click Recall.

Recalling the Configuration on the MP-M80 - PC

  1. Establish a network connection to the MP-M80.
  2. With MP Install, navigate to MENU > CONFIGURATIONS.
  3. Select the configuration listed in App Storage.
  4. Copy the configuration from App Storage to the Internal Storage.
  5. Once copied, select the configuration and click Recall.